Description
This diode laser stack 10bar Model C for hair removal which has 10bars with a aluminum shell. The water hole is at the bottom. The electrode is on the back.
It is used for most of diode laser hair removal machine from China. wavelength 808 or mix wavelength as 755nm, 808nm and 1064nm.
This diode laser stack usually burn out after working 1year. Then it need to be refresh. Or you can buy a new one to replace the old one.
Repairing procedure | Advantages |
>Chioce A: Send the old broken handpiece to our facatory. We will do the process of checking , repairing, cleanning and etc. Then send the fresh new handpiece back to you. | >Save Money. Replace the broken diode stack only. Low cost and convenient |
>Chioce B: if you have basic assambly capacity, you can send the diode laser stack only to our factory. We remove the old bar and mount the new bar to recover the laser power of the stack. | >Long life time. we use diode laser bars from Germany. The newest Ausn mounting technology will be applied when repairing. After repair. The handpiece will be as a new one. life time is much longer than before |
>Choice C: Measure your stack and comfrim the water pipe hole and screw hole position. Then press the button below to buy a ready-made stack which is match your old hadnpiece. | >All technical support available. We major in diode laser mounting, software, spare parts over 16 years. All the technologies about laser hair removal machine are open to you. |
Specification:
Model No. | VS-MA-10-1.0-Model C |
Application | laser hair removal handpiece Repair And Replacement |
Operation Mode | CW |
Power per submounts | 50W |
Number of submounts in one stack | 10bars |
Central wavelength at 25℃ | 808 ± 2nm |
Typical Operation current | 40A |
Maximum Operating current | 50A |
Typical Threshold current | 8A |
Maximum Operating Voltage | <20V |
Fast Axis Divergence (FWHM) | 39º |
Slow Axis Divergence (FWHM) | 8º |
Operation Condition | non-condemsing atmosphere, cleaning room |
Expected lifetime | 10 millions shots |
Typical pitch per bar | 2mm |
Cooling requirement | |
Flow rate | >3.5L/min |
Water Temperature | 27+-3°C |
Water Quality | pure water |
cooling system | Do not use any material that combination with copper would form galvanic elements |